Calibrators
HOME
ABOUT US
About Us

CONTACT US

Frequency Calibrator

Panel Mount

Multi Function Calibrators

Model 541

Frequency Calibrator

with Totalizer

Accuracy: ± 0.005% of range


Totalize inputs / outputs from

1 to 99999 pulses in

1.0 to 100.0 minutes


5 ranges from 1 CPH (Count-Per-Hour) to

20.000 KHz for source and read


Gate trigger LED flashes in synch with the output frequency to calibrate optical pickups.

This also allows easy adjustment of the

attenuation for proper gate triggering.


Superior battery life of 45 hours under typical continuous usage


Includes leads, carry case & NIST certificate


Models 820PM & 830PM

Multi-Function Calibrators

Panel Mount

820PM - Calibrate milliamps and voltage

Source 0.00 to 24.00 mA, 0.00 to 10.25 VDC and 0.00 to 80.00 mV

Read to 24.00 mA, 00.00 to 10.,25 VDC, 0.0 to 60.0 VDC, 00.00 to 80.00 mV

Simulate 2 Wire transmitters

Power up transmitters and loops with built in 24 V power supply

Simplify HART hook ups with built in 250 ohm resistor


830PM - as above plus

Patented diagnostics including Current Leak detection;  LOOPSCOPE which indicates loop current, voltage and resistance

Auto detection of RTD connections

Ability to operate as an Isolated Transmitter


PIE 820PM, 830PM.pdf PIE 541 Freq.pdf

Thermocouple Calibrators

Model 322-1

Source & Read

Source & read 4 T/C

types plus mV

Resolution to 0.1 °F & °C; Accurate to 0.2°


Models 422 & 422 Plus

Automated T/C Calibrator

Source and Read 14 T/C

types plus mV

Resolution to 0.1 °F & °C; Accurate to 0.2°

Model 520B

T/C calibrator, source only

Types J, K, E, T, R, S, B, N,

G, C, D, L, U and P

Adjustable temperature output in selectable 0.1°C or 0.1°F steps

Model 521B

T/C calibrator, source 14 Types

Types J, K, E, T, R, S, B, N, G,

C, D, L, U and mV

Adjustable temperature output in selectable 0.1°C or 0.1°F steps


All models come with leads & NIST certificate.

Models 322 & 422 also include a rubber boot & carry case.

Dual channel display on

Model 422 Plus

PIE 322 TC.pdf PIE 422 Plus.pdf PIE 520B-521B TC.pdf PIE 520B-521B TC.pdf

RTD Calibrators

Models 311 & 311 Plus

Automated Source & Read

Source & read mulitiple RTD curves

Automatically detect 2, 3 or 4 wires

Compatible with all instruments

311 Plus with secondary display

 

Model 211

Automated Source & Read

Source & read mulitiple RTD curves

Automatically detect 2, 3 or 4 wires

Guaranteed compatible with all

Instruments including Rosemount

Model 510 B

RTD Simulator

Simulates RTD resistances into all

types of process instruments

Accurate to ±0.25°C (±0.5°F) for Pt 100 Ohm RTD’s with 0.1° Resolution

Model 511 B

10 x RTD + Ohms Simulator

Source 10 RTD curves with Direct Temperature Output or Ohms

Works with a wide variety

of smart transmitters

All models come with leads & NIST certificate.

Models 211 & 311 also include a rubber boot & carry case.

Patented Current Leakage Test on

Model 311 Plus

PIE 211 RTD.pdf PIE 311, 311 Plus.pdf PIE 510B-511B RTD.pdf PIE 510B-511B RTD.pdf

Model 532

Loop Diagnostics - ma & V

Lab accuracy

Current - 0.012% OR + 0.002 ma

Volts - 0.012% OR + 0.004 V

Take “live” readings


Milli-amp & Voltage Calibrators

Model 235

Voltage Calibrator

Source & read DC Volts

Calibrate recorders in live loops

Source pH

Accurate to 0.02% of reading

Model 535

Volt & Dual Milli-amp Calibrator

Calibrate 4-20 ma, 0-50 ma & Volts

Lab accuracy

Accurate to 0.025% of reading

Built-in 45 volt power supply

All models come with leads, carry case & NIST certificate.

Model 235 also includes a rubber boot.

Patented Current Leakage Test on

Model 532

PIE 235 Volt.pdf PIE 532-mA-V.pdf PIE 535 10-50mA, 4-20-mA, V.pdf

Milli-amp Loop Calibration & Diagnostics

Model 134

Loop Calibrator

Small size, big performance

Source milli-amps

Pocket size with built-in belt clip

Accurate to 0.05% +0.01 ma


Model 334

Loop Calibrators

Loop calibrator

Calibrate with lab accuracy

Source milli-amps

Back-lit display

Model 434

Automated Diagnostic Calibrator

Automated loop calibrator

Calibrate with lab accuracy

Accurate to 0.01%  of reading

Plus 0.002 ma

Model 334 Plus

Loop Calibrators

Automated loop calibrator

Calibrate with lab accuracy

Automatic output stepping

And ramping

All models come with rubber boot & NIST certificate.

Model 434 also includes  a carry case

Patented Current Leakage Test on

Models 334 Plus & 434

PIE 134.pdf PIE 334 Plus mA.pdf PIE 434, 4-20-mA.pdf PIE 334 mA.pdf

Process Calibrators

Multi-Function


Model 850

All-In-One

High Accuracy Diagnostic Calibrator for

4-20 & 10-50mA. Sources & reads T/C, RTD, V, mV, and Frequency.  

Also sources pH & calibrates pessure.

Many other features.

PIE Calibrator Catalogue

Calibrator types & combinations -

Ma - Volt - ma&Volt - TC - RTD - TC&RTD - Frequency - Multifunction

All models come with rubber boot, leads, carry case & NIST certificate

Technician friendly with Unique EZI-dial start

Patented Current Leakage Test on

Models 820 Elite, 830 & 850

Model 525B

Automated RTD & T/C Calibrator

Calibration lab accurate & stable

Compatible with all process instruments

Calibrate to 0.1 or 0.01 deg F or C

Use in the workshop, plant or field

Models 820 & 820 Elite

820

Ma, V, Frequency, T/C, RTD, Continuity


820 Elite

As above plus pH, resistance, pressure

Model 830

Milliamp, Volts, Frequency, pH, Ohms,

RTD, T/C, Pressure, Loop

Diagnostics,Transmitter Supply

Simultaneously displays current, Voltage & Resistance in a live loop

PIE 820, 820 Elite.pdf PIE 525B TC & RTD.pdf PIE 830 MF.pdf PIE 850 MF.pdf